HARDWARE MONITORING
HARDWARE
MONITORING
Hardware Monitor Status
Watchdog Timers
BMC Reset
15-4
This section includes Hardware Monitor Status display setup, Watchdog
Timer setup and BMC Reset.
This page is for monitoring status display.
1. Login to Enterprise Manager. Select Maintenance > System
Maintenance > Hardware Monitoring.
2. Select the Hardware Monitor Status tab.
3. To monitor a component click to check mark the box then, click on the
Activate icon. The Monitoring Status column will show the
component status.
4. To stop monitoring a component click to check mark the box then,
click on the Deactivate icon. The Monitoring column will show
Detection Stop.
5. The Activate or Deactivate change is set immediately.
This tab is used to set the action the system will take if a watchdog timer
expires.
1. Login to Enterprise Manager. Select Maintenance > System
Maintenance > Hardware Monitoring.
2. Select the Watchdog Timers tab.
3. Use the pull-down list to select the Expiration Action.
No Action = No action will occur.
Reboot Without Power Off = When a timer expires the server will
reboot
Reboot With Power Off = When a timer expires the server will shut
down, power down then, reboot
4. Click on the Save icon.
Click on the Reset icon to reset the BMC processor on the IPMI card in
the IPedge server. This should be done only on the advice of a Toshiba
engineer. The BMC takes a few minutes to reset. While the reset is
processed there is no monitoring by the BMC.
Hardware Monitor Status
Installation Manual