Introduction - Keithley 2016 User Manual

Thd multimeter
Table of Contents

Advertisement

E-2
IEEE-488 and SCPI Conformance Information

Introduction

The IEEE-488.2 standard requires specific information about how the Model 2016
implements the standard. Paragraph 4.9 of the IEEE-488.2 standard (Std 488.2-1987) lists the
documentation requirements.
the information or references the manual for that information.
commands used by the Model 2016.
The Model 2016 complies with SCPI version 1991.0.
SCPI confirmed commands, and the non-SCPI commands implemented by the Model 2016.
Table E-1
IEEE-488 documentation requirements
Requirements
(1)
IEEE-488 Interface Function Codes.
(2)
Behavior of 2016 when the address is set outside the
range 0-30.
(3)
Behavior of 2016 when valid address is entered.
(4)
Power-On Setup Conditions.
(5)
Message Exchange Options:
(a)
Input buffer size.
(b)
Queries that return more than one response message
unit.
(c)
Queries that generate a response when parsed.
(d)
Queries that generate a response when read.
(e)
Coupled commands.
(6)
Functional elements required for SCPI commands.
(7)
Buffer size limitations for block data.
(8)
Syntax restrictions.
(9)
Response syntax for every query command.
(10)
Device-to-device message transfer that does not follow
rules of the standard.
(11)
Block data response size.
(12)
Common Commands implemented by 2016.
(13)
Calibration query information.
(14)
Trigger macro for *DDT.
(15)
Macro information
(16)
Response to *IDN (identification).
(17)
Storage area for *PUD and *PUD?
(18)
Resource description for *RDT and *RDT?
(19)
Effects of *RST, *RCL and *SAV.
(20)
*TST information.
(21)
Status register structure.
(22)
Sequential or overlapped commands.
(23)
Operation complete messages.
Table E-1
provides a summary of the requirements, and provides
Description or reference
See
Appendix
Cannot enter an invalid address.
Address changes and bus resets.
Determine by :SYSTem:POSetup
256 bytes.
None.
All queries (Common Commands and SCPI).
None.
See
Table
E-2.
Contained in SCPI command subsystems tables
(see
Table 5-2
Block display messages: 12 characters max,
See "Programming Syntax" in
See "Programming Syntax" in
None.
See "Display Subsystem" in
See "Common Commands" in
See Service Manual.
Not applicable.
Not applicable.
See "Common Commands" in
Not applicable.
Not applicable.
See "Common Commands" in
See "Common Commands" in
See "Status structure" in
All are sequential except :INIT and :INIT:CONT ON,
which are overlapped.
*OPC, *OPC? and *WAI; see "Common Commands"
in
Section
Table E-2
lists the coupled
Table 5-2
through
Table 5-11
D.
(Section
through
Table
5-11).
Section
4.
Section
4.
Section
5.
Section
4.
Section
4.
Section
4.
Section
4.
Section
4.
4.
list the
5).