Voltage Regulator Check; Recharge System Voltage Check; Starter Motor - Gilera Runner RSTPurejet Service Manual

Table of Contents

Advertisement

Runner RST Purejet

Voltage regulator check

With the battery fully charged, measure the volt-
age in the battery poles with engine at high speed.
The voltage must not exceed 15.2 volt.
If higher voltage is found, replace the regulator.
At voltage less than 13 volt, proceed with checks
on the stator and relevant wiring.

Recharge system voltage check

Connect an ammeter induction clamp to the volt-
age regulator positive cable. Measure the battery
voltage and turn on the lights with the engine off
and wait until the voltage settles at around 12 volts.
Start the engine and measure the current distrib-
uted by the circuit with the lights on and engine at
high rpm.
If the current value is less than 10A, repeat the test
using a new regulator and/or stator instead.

Starter motor

Specifications
- Rated voltage 12V.
- Rated power 0.25 kW.
- Left rotation viewed from pinion side.
- Connection to engine with pinion and crown
wheel on transmission side crankshaft.
- Control with button
Tests to perform to check the electrical starter
Static test
Remove the left side panel.
Check the resistance of the induced brush unit.
Reference value: < or equal to 1 Ohm
- Use a lift to adequately support the vehicle.
- Remove the stand and support.
Electrical system
ELE SYS - 11