mamdt.bk : mamdt3.fb4 Page 68 Tuesday, August 5, 1997 4:20 PM
If the Hard Disk Activity
Light Does Not Work
WARNING
3 Troubleshooting Your PC Workstation
If Your PC Workstation Has a Hardware Problem
If Your Hard Disk Does Not Work
Check that the disk power and data cables are correctly connected
•
(refer to page 35).
For an IDE drive, check the IDE Devices configuration settings in the
•
Setup program (Advanced IDE Devices).
For an IDE drive, check the Hardware Protection settings in the
•
Setup program (Security Hardware Protection).
For an IDE drive, check the Boot Device Security settings in the
•
Setup program (Security Boot Devices Security).
For a SCSI drive, check the SCSI Interface setting in the Setup
•
program (Advanced Integrated SCSI Interface). You can also
access this setting by pressing
(POST).
If the hard disk activity light does not flicker when the PC Workstation
is accessing the hard disk drive:
Check that the control panel connector is firmly attached to the
•
system board.
Check that the disk power and data cables are correctly connected
•
(refer to page 35).
If there is a Problem with Your CD-ROM Drive
Make sure that you disconnect the power cord and any
telecommunications cables from your computer before you remove
the cover to check the cable connections or jumper settings.
To avoid electric shock and harm to your eyes by laser light, do not
open the CD-ROM drive enclosure. The CD-ROM drive should be
serviced by service personnel only. Refer to the label on the CD-ROM
for power requirements and wavelength. This PC Workstation is a class
1 laser product. Do not attempt to make any adjustment to the laser
unit.
68
English
during the power-on self test