Creating an LED Script
LED Script
Cisco Small Business SPA 300 Series, SPA 500 Series, and WIP310 IP Phone Administration Guide
The LED script describes the color and blinking pattern of a Line Key LED. Each
script contains a number of fields separated by a semicolon(;). White spaces are
ignored. Each field has the syntax <field-name> = <field-value>. The allowed
field-name and corresponding field-values are listed below:
c=o|r|g|a
This field sets the color of the LED. The 4 choices are:
o = off
r = red
g = green
a = amber (orange)
p=n[b]|s[b]|f[b]|d[b]|u[d]
This field sets the blinking pattern of the LED. The 4 choices are:
nb = no blink (steady on or off)
sb = slow blink (1s on and 1s off)
fb = fast blink (100ms on and 100ms off)
ud = user-defined (according to the contents of the u field)
u=on/off/on/off/etc.
This is a user-defined blinking pattern used only when p = ud. It consists of up to 4
pairs of on/off duration in seconds with up to 2 decimal places; each value is
separated by a forward slash (/).