4.3.9 Test Menu Options and Parameters

TX TEST PATTERN
RX TEST PATTERN
PATTERN SYNC
TST PAT ERR CNT
TST PATT BER
RESTART TST PAT ((ENTER))
LOOPBACK
TM110 – Rev. 1.3
TXIF
TXLBAND
ENH ASYNC
IDR
SEQ
RS
RS CUSTOM
IBS
D&I
AUPC
8PSK
16QAM
TURBO 52 MBPS
DVB
EDMAC
{NONE, 2047, 2^15-1, 2^23-1}
Allows the user to enable the tests listed above.
{NONE, 2047, 2^15-1, 2^23-1}
Allows the user to enable the tests listed above.
{YES, NO}
Yes indicates that the RX Test Pattern is in sync.
{NO SYNC, nnnn x 10
Displays the number of errors detected by the test
pattern checker.
{NO SYNC, nnnn x 10
Displays the measured BER for the test pattern.
Allows the user to restart the test by pressing <ENTER>
on the keypad.
{IF, TERR TX/RX, BASEBAND TX/RX, NONE,
TERR RX, BASEBAND RX, TERR TX, BASEBAND TX,
IFEC TX}
Terrestrial Loopback is performed at the Terrestrial
Interface.