User Interfaces
EBNO
RX LEVEL
IBS BER
RX DVB FRM LOCK
COMMON (menu)
TERR FPGA CFG
CODEC FPGA CFG
CODEC DEV CFG
VOLTAGE (menu)
+1.5V RX SUPPLY
+1.5V TX SUPPLY
+3.3V SUPPLY
+5V SUPPLY
+12V SUPPLY
-12V SUPPLY
+20V SUPPLY
EXT CLOCK ACT
EXT REF ACT
EXT REF LOCK
CLEAR LATCHED ((ENTER)) Allows the user to reset the latched alarms by pressing
BACKWARD ALARMS
For the following alarms:
alarm. FRC allows the user to force the alarm locally.
4-28
<ENTER> on the keypad.
Backward alarms are alarms that are fed back to or
received from the other end of the satellite link. In IBS
Mode (including Drop & Insert), Backward Alarm 1 is the
only one used. It would be received if the distant end
demod drops lock.
RCV = YES indicates a received backward
DMD2050 Universal Satellite Modem