Actual Overhead Rate Calculation - Radyne DMD2050 Operation Manual

Universal satellite modem
Hide thumbs Also See for DMD2050:
Table of Contents

Advertisement

DMD2050 Universal Satellite Modem
User Data
Rate
512,000
1,024,000
2,048,000
3,072,000
4,096,000
6,312,000
6,312,000
6,312,000

3.20.4 Actual Overhead Rate Calculation

The following is the actual calculation the modem does to calculate the overhead ratio:
1.
The modem calculates the minimum in-band rate to limit the size of the user data slots to
2,500 bits (the result is truncated to an integer).
Minimum In-Band = (User Data Rate * Control Ratio)/((Control Ratio + 1) * 250)
2. Using the bigger of Minimum In-Band or the selected In-Band, the modem calculates the
number of bits for each user data slot (result is truncated to an integer).
Slot Bits = (User Data Rate * (Control Ratio * 10))/(In-band Rate * (Control Ratio + 1))
The actual ratio the modem uses is:
Actual Ratio = (Slot Bits + 10)/Slot Bits
Example 1:
User Data Rate:
In-Band Rate:
Control Ratio:
Minimum In-Band = (1,024,000 * 7)/((7 + 1) * 250) = 3,584
Slot Bits = (1,024,000 * (7 * 10))/(19,200 * (7 + 1)) = 466
Actual Ratio = (466 + 10)/466 = 1.021
Example 2:
User Data Rate:
In-Band Rate:
Control Ratio:
Minimum In-Band = (6,312,000 * 7)/((7 + 1) * 250) = 22,092 (
Slot Bits = (6,312,000 * (7 * 10))/(22,092 * (7 + 1)) = 2,500
Actual Ratio = (2,500+ 10)/2,500= 1.004
TM110 – Rev. 1.3
In-Band
Control
Rate
Ratio
19,200
1/7
19,200
1/7
19,200
1/7
19,200
1/7
19,200
1/7
19,200
1/7
19,200
1/3
19,200
1/1
1,024,000 bps
19,200 bps
1 to 7
6,312,000 bps
19,200 bps
1 to 7
Theory of Operation
Aggregate Data
Overhead
Rate
533,974
1,045,974
2,069,951
3,093,943
4,117,951
6,337,248
6,337,606
6,350,418
(less than In-Band Rate)
more than In-Band Rate)
Ratio
1.043
1.021
1.011
1.007
1.005
1.004
1.004
1.006
3-29