Radyne DMD2050 Operation Manual page 48

Universal satellite modem
Hide thumbs Also See for DMD2050:
Table of Contents

Advertisement

DMD2050 Universal Satellite Modem
The IBS Async Framer Data Mode provides a service channel between the two sites of a link
permitting the modem processors to send messages and get responses over this channel. AUPC
can be set to operate on either or both directions of a link but always requires a bi-directional
channel. Therefore, both the Modulator and Demodulator interface mode must be set to IBS
Async for the AUPC Menus to be visible and for the AUPC function to operate properly. The
AUPC Functions and their descriptions are shown on Table 3-2.
Function
AUPC ENABLE/DISABLE
AUPC Eb/No
AUPC MIN LVL
AUPC MAX LVL
AUPC DEF LVL
The AUPC Menus are located under the Modulator Menu as shown in Section 4. The
EFAUPC Menu displays when EFAUPC Framing is enabled.
The basic AUPC Operation is described as follows:
Assume that the two modems, one at each end of the link, are set to AUPC operation. Only one
direction is discussed, but the same functions could be occurring in both directions
simultaneously. Modem "A" is transmitting to modem "B" under normal conditions and modem
"B" has a receive E
/N
b
o
of 7.5 dB, and is currently outputting –15 dBm. Next, it begins raining at location "B", and the
E
/N
drops to –7.0 then –6.8 dB. Modem "B" is constantly sending update messages to "A" and
b
o
reports the current E
/N
b
power, and raises it again when it sees further drops. As the rain increases in intensity, and the
E
/N
decreases again, "A" continues to increase its power level to compensate, and when the
b
o
rain diminishes and quits, it lowers its power level to compensate. The operation is therefore a
feedback control loop with the added complication of a significant time delay.
There are safeguards built into the AUPC System. First, the Modulator has two additional
parameters, which allow control of the Maximum and Minimum Power Output Levels. Second, a
default power level is specified which takes precedence over the output power level during signal
loss or loss of AUPC Channel Communication. The default power level should normally be set to
a high enough level to reestablish communication regardless of rain fade. The other controls are
built into the operating control software to limit response times and detect adverse operating
conditions.
TM110 – Rev. 1.3
Table 3-2. AUPC Functions
Enables/Disables the AUPC to function locally
Sets minimum output power to be used
Sets maximum output power to be used
Sets default output power to be used
of 7.5 dB. Modem "A" has been set to an AUPC E
. When "A" sees the drop in E
o
Description
Desired E
/N
of remote modem
b
0
/N
, it slowly begins to raise the output
b
o
Theory of Operation
/N
on the Front Panel
b
o
3-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents