DMD2050 Universal Satellite Modem

2.5.1 Initial Power-Up

Before initial power up of the DMD2050, it is a good idea to disconnect
the transmit output from the operating ground station equipment. This is
especially true if the current Modulator Configuration Settings are
unknown,
where
communications traffic. New units from the factory are normally shipped
in a default configuration which includes setting the transmit carrier off.
Turn on the unit by placing the Rear Panel Switch (located above the power entry connector) to
the On Position. Upon initial and subsequent power-ups, the DMD2050 Microprocessor will test
itself and several of its components before beginning its Main Monitor/Control Program. These
power-up diagnostics show no results if successful. If a failure is detected, the Fault LED will
illuminate.
The initial field checkout of the modem can be accomplished from the Front Panel or in the
Terminal Mode. The Terminal Mode has the advantage of providing full screen access to all of
the modem's parameters, but requires a separate terminal or computer running a Terminal
Program. The Terminal Mode is enabled from the front panel in the System M&C Submenus.

2.5.2 Factory Terminal Setup

The factory terminal setup is as follows:
Emulation Type:
Baud Rate:
Data Bits:
Parity:
Stop Bits:

2.6 Storage

It is recommended that the unit be stored in its original sealed packing. The unit should be stored
in a dry location where the temperature is stable, away from direct contact with rain, snow, wind,
sun, or anything that may cause damage.
TM110 – Rev. 1.3
incorrect
settings
could
VT-100 (can be changed)
19.2 K (Can be changed via Front Panel)
8
No Parity (Fixed)
1 Stop Bit
Installation
disrupt
the
existing
2-5