Operating Overview – Connections, Keys, Rotary Switch, Symbols
Symbols and Functions for Rotary Switch Positions (MD: main display, AD: auxiliary display, MR: measuring range)
Switch
FUNC Display
V~
0/4
V~AC TRMS / HZ
A~AC TRMS
V~
1
Hz ~AC TRMS /
V~
2
V filter ~AC TRMS / Hz man
1kHz
dB
3
dB ~AC TRMS
V
0/4
V DC /
V
1
V DC+AC TRMS / CF /
V
2
V DC EVENTS
V
3
V~AC TRMS EVENTS
PQ
0/2
MAinS: V DC+AC TRMS
1
thd % ~AC TRMS / V /
thd % ~AC TRMS / A /
MHz
0/2
MHz
%
1
%
0/3
nS
1
nS
RPE
2
0/2
1
V DC
Temp. TC
0/2
C, type K
Temp. RTD
1
°Pt100
0/2
nF
m
1
km
W
0/2
W
DC+AC TRMS / V+A / PF
Wh
1
Wh
DC+AC TRMS energy time Energy: energy (active, reactive, apparent energy) / on-time
A
0/4
A DC+AC TRMS /
A /~
1
A DC /
A~
2
A~AC TRMS / Hz /
A /~
3
thd % ~AC TRMS / A
12
Measuring function
CLiP=OFF: alternating voltage, AC TRMS, full bandwidth
(0/2)
CLiP=ON: alternating current via current clamp sensor, TRMS AC value
(1)
CLiP=oFF: voltage frequency, to 300 kHz / CLiP=ON current frequency sensor
Alternating voltage, AC TRMS, with low pass filter (1 kHz)
Alternating voltage level measurement
(0/2) CLiP=OFF: direct voltage measured directly / CLiP=ON: via current clamp sensor
(1) CLiP=OFF: pulsating voltage, direct, TRMS / CLiP=ON: via current clamp sensor
Direct voltage events
Alternating voltage events
Mains quality: events (type, start time, date, duration, value)
Main display: total harmonic distortion relative to fundamental frequency as %
(0/2)
Auxiliary display: RMS value for the total signal in V
(High) Frequency at 5 V~ up to 1 MHz
Duty cycle at 5 V~
(DC) resistance
Conductivity (in nano-Siemens)
Low-resistance measurement with acoustic signal where Iconst = 3 mA
Continuity test, , with acoustic signal where Iconst = 1 mA
Diode voltage up to max. 6 V where Iconst = 1 mA
Temperature, type K thermocouple
Temperature with Pt100 / Pt1000 resistance sensor
Capacitance
Cable length
Power (active, reactive, apparent power) / voltage + current / power factor
Mean: average power / max: maximum power
(2)
CLiP=OFF: pulsating current, direct, TRMS AC+DC, CLiP=ON: current clamp transformer
(3)
CLiP=OFF: direct voltage, direct, CLiP=ON: direct voltage via current clamp trans.
(0/4) CLiP=OFF: alternating current direct, TRMS AC / current frequency,
CLiP=ON: alternating current via current clamp trans. // temperature: MB 6 A and 10 A
(1)
Main display: total harmonic distortion relative to fundamental frequency as %
Auxiliary display: RMS value for the total signal in A
Sub-Function
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO
DATA/MIN/MAX, MAN/AUTO
Event querying: keys
Query harmonics 1 through 15: RMS values
and distortion via keys
DATA/MIN/MAX, MAN/AUTO
DATA/MIN/MAX
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX
DATA/MIN/MAX, ZERO
DATA/MIN/MAX, ZERO
DATA/MIN/MAX
DATA/MIN/MAX
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, W – VA – VAr: vw
MAN/AUTO, Wh – VAh – VArh: vw keys
Energy – Mean – max: , ZERO = reset
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
DATA/MIN/MAX, MAN/AUTO, ZERO
Query harmonics 1 through 15: RMS values
and distortion via keys
GMC-I Messtechnik GmbH
Need help?
Do you have a question about the METRAHIT ENERGY TRMS System Multimeter and is the answer not in the manual?