Vertical Terminations - Co-Linear Flex System - Masport FireGenie PG33-NG Owners & Installation Manual

Table of Contents

Advertisement

INSTALLATION
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to two
3" (76mm) co-linear aluminium flex running the
full length of the chimney. See the Flueing
Arrangements on next page for minimum and
maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Flue Adaptor
945
45
o
Elbow
Alternate Approved Caps
980
Vertical Termination Cap
991
High Wind Cap
923GK 3" Co-linear Adapter with flashing
FPI Cabinet and/or Flat Wall Mantles
may be used in these applications
ensuring that clearances to com-
bustibles are maintained.
22
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
Masonry chimneys may take various contours which the flexible liner will accommodate.
However, keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
of two certified
Outer
Pipe
with Kit#
946-563
Pipe Length
Flue Adaptor
# 510-994
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Exhaust
Flue
o
45 Elbow
Inner Pipe
Adapter
with Kit#
946-563
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563
Masport PG33 Gas Inbuilt

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firegenie pg33-lpg

Table of Contents