Horizontal Terminations Only - Masport FireGenie PG33-NG Owners & Installation Manual

Table of Contents

Advertisement

This flueing system, in combination with the PG33 Direct Flue Gas Fireplace, have been tested and listed as a direct flue heater system by AGA.
The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram on page 10.
Masport Direct Flue (Flex) System Termination Kit (Part # 946-513) includes all the parts needed to install the PG33 with a maximum
run of 2 feet. If installing the P33 with a continuous flue length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) using Kit # 946-515 (4 ft)
or 946-516 (10 ft) or see page 13 for alternate flueing arrangements.
1) 6-7/8" dia. flexible liner (2 ft. length)
2) 4" dia. flexible liner (2 ft. length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner sections should be continuous without
any joints or seams.
2) Only Flex pipe purchased from Masport may
be used for Flex installations.
IMPORTANT
If using any Cabinet Mantels with Part # 510956, 510958,
510962, 510964 and 510834 the wall thimble must be
secured first and flueing must be attached to unit before
sliding into final position.
Also Simpson Dura-Flue flueing cannot be used with any
of the mantels noted above.
Minimum Flex Kit Center-Line
(NG & LPG)
Masport PG33 Gas Inbuilt
MASPORT DIRECT FLUE SYSTEM (FLEX)

HORIZONTAL TERMINATIONS ONLY

4" (102mm)
dia. flue pipe
(173mm)
dia. Flue pipe
Wherever necessary due to exter-
nal location of cap, the AstroCap
can be replaced with the FPI Riser
Flue Termination Cap or the Dura-
Vent Snorkel Termination Cap.
Minimum Flex Kit Center-Line
(ULPG)
INSTALLATION
Wall Thimble (2 pc)
(required in
Canada only)
spring
spacer
6-7/8"
Alternate Horizontal
Termination Caps
IMPORTANT NOTE
If the Burner is not a ULPG Burner,
a minimum flue rise of 1260mm
(total height from the floor) MUST
BE adhered to.
TM
AstroCap
Termination Cap
(Part# 946-523/P)
See also
Figure 1 below.
Figure 1
11