Flueing - Simpson Dura-Flue System; Horizontal Or Vertical Terminations - Masport FireGenie PG33-NG Owners & Installation Manual

Table of Contents

Advertisement

The Simpson Dura-Flue Direct Flue System offers
a complete line of component parts for installation
of both horizontal and vertical installations. Many
items are offered in decorative black, as well as
galvanized finish. We recommend using the galva-
nized finish for installation with the PG33.
The minimum components required for a basic
horizontal termination are:
1
AstroCap Horizontal Termination Cap
o
1
45
Elbow
1
Flue Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness (see
chart)
For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create
a level surface to mount the flue terminal. The
Terminal must not be recessed into siding.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
TM
The Masport AstroCap
is certified for installa-
tions using FPI flueing systems as well as Simp-
son Dura-Vent® and Direct Vent GS.
Masport
TM
, and Masport AstroCap
proprietary trademarks of FPI Fireplace Prod-
ucts International Ltd.
Dura-Vent® and Direct Vent GS are registered
and/or proprietary trademarks of Simpson Dura-
Vent Co. Inc.
Alternate
Horizontal
Termination
Caps
Wherever necessary due to external
location of cap, the AstroCap can be
replaced with the FPI Riser Vent Termi-
nation Cap or the Dura-Vent Snorkel
Termination Cap.
Masport PG33 Gas Inbuilt
SIMPSON DURA-FLUE FLUEING

Horizontal or Vertical Terminations

Vertical
Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
TM
are the
Flat Wall Installation
Max. Wall
Thickness
7-1/4" (184mm)
10-1/4" (260mm)
13-1/4" (337mm)
12-1/4" - 15-7/8"
(311mm - 641mm)
18-1/4" - 25-1/4"
(464mm - 381mm)
Vinyl Siding
Standoff (Optional)
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
o
90 Elbow
24" (610mm)
Pipe Length
Wall Thimble
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
o
45 Elbow
Flue Adapter
Simpson Dura-Flue
Direct Flue GS
Flue Length
Required
6" (152mm)
9" (229mm)
12" (305mm)
11" - 14-5/8" Adj. Pipe
(279mm - 371mm)
11" - 14-5/8" Adj. Pipe
(279mm - 371mm)
INSTALLATION
Horizontal
Termination
Cap
Wall Thimble
Horizontal
Termination Cap
Vinyl Siding
Standoff (Optional)
13