Conversion To Ulpg With Burner - Masport FireGenie PG33-NG Owners & Installation Manual

Table of Contents

Advertisement

Conversion Kit #436-965 for NG to ULPG with Dedicated ULPG Burner
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit 436-967 Contains:
Qty. Part #
Description
1 904-575 Burner Orifice #55
1 918-273 Red "ULPG" label
2 918-272 Label "Converted to ULPG"
1 918-376 Instruction Sheet
1 910-920 ULPG Pilot Orifice
1 436-526 Burner Assembly ULPG
1) Shut off the gas supply and unplug the
power cord.
2) Carefully remove the glass, logs and lava
rock.
3) Remove burner. See important note on page
11 and 18.
4) Remove burner orifice with a 1/2" wrench
and discard. Use a wrench to hold on to the
elbow behind the orifice.
5) Reinstall new burner orifice stamped #55
and tighten.
Burner Orifice
6) Remove the rear log tray.
7) Remove the 2 screws which secure the
pilot.
Rear Log Tray
8) Lift the pilot assembly and remove the pilot
tube from the pilot assembly using a 11mm
wrench.
Masport PG33 Gas Inbuilt
9) Remove the NG pilot orifice and replace it
with the ULPG orifice.
10) Re-install the pilot tube to the pilot assem-
bly.
Pilot
Pilot
Pilot
Tube
Orifice
Extrusion
Tube
11) Re-install the pilot assembly over the pilot
extrusion tube and secure it with 2 screws.
12) Re-install the rear log tray.
13) Adjust the burner aeration setting to fully
open and re-install the original with the
ULPG burner OR maintain minimum vent
configurations as outlined on page 11 or 18.
14) Open the bottom louvre.
15) Stick the conversion label "This unit has
been converted to ULPG" over top of the
serial number decal.
16) Replace the yellow "NG" label with the red
"ULPG" label.
17) Remove the screw from the module and pull
off the module cover.
screw
module cover
18) Pull out the 2 orange wires attached to the
valve, and the connector from the module.
orange connector
connector
wires
INSTALLATION
19) Carefully pull out the control box.
20) Remove the heat sheild from the control box
by removing the 2 screws.
NOTE: The control box is held in place with
Pilot
Assembly
heat sheild
velcro.
21) Remove the control box cover by undoing
the 3 screws. Maneuver through antenna.
Antenna
Control Box
Cover
22) Remove the jumper using a plier.
Jumper
23) Stick the conversion label "This unit has
been converted to ULPG" on the control
box cover.
control box
Jumper Location
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firegenie pg33-lpg