FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-FLUE DIRECT FLUE GS SYSTEM and
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45
equal one 90
o
elbow).
Note: Must use optional flue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)
Minimum
Simpson Dura-Flue Center-Line
Masport PG33 Gas Inbuilt
MASPORT DIRECT FLUE SYSTEM (FLEX)
(NG, LPG & ULPG with ULPG Burner)
Maintain clearances to combustibles.
Horizontal flue must be supported every 3 feet.
Firestops are required at each floor level and whenever passing through a wall.
Minimum Flex Kit Center-Line
INSTALLATION
o
and one 90
o
elbow (two 45
A flue guard should be used whenever
the termination is lower than the specified
minimum or as per local codes.
Note: Masport Direct Flue System (Flex)
is only approved for horizontal ter-
minations.
Important
If using any Cabinet Mantels with
Part # 510956, 510958, 510962,
510964 and 510834 the wall thimble
must be secured first and flueing
must be attached to unit before slid-
ing into final position.
Also Simpson Dura-Flue flueing
cannot be used with any of the man-
tels noted above.
o
elbows
17