Advertisement

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been
tested in accordance with AG 103,
NZS 5262 and have been certified
by the Australian Gas Association
for installation and operation as
described in these Installation and
Operating Instructions.
Your unit should be serviced
annually by an authorised
service person.
P33 Gas Inbuilt
Roma
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper
installation,
alteration, service or maintenance can
cause injury or property damage. Refer to
this manual. For assistance or additional
information consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the vicinity
of this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
Head Office - New Zealand
1-37 Mt Wellington Hwy.Panmure,
P.O. Box 14349
Auckland 6.
918-046d
FOR YOUR SAFETY
adjustment,
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
Australia
P.O. Box 533
Braeside, Victoria, 3195
Model:
P33R-NG1
P33R-LPG1
01/16/04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P33R-NG1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Masport P33R-NG1

  • Page 1 Owners & Installation P33 Gas Inbuilt Model: Roma P33R-NG1 P33R-LPG1 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, What to do if you smell gas: alteration, service or maintenance can Do not try to light any appli- cause injury or property damage.
  • Page 2 Congratulations! You are the owner of a state-of-the-art Gas Fireplace by MASPORT LTD. The P33R-1 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P33R-1 has been approved by Warnock Hersey for both safety and efficiency.
  • Page 3: Table Of Contents

    Exterior Flue Termination Locations ......10 Removing Valve ............28 Flueing Introduction ........... 11 Installing Valve ............28 Flueing - Masport Direct Vent System Horizontal Terminations ........11 Parts List Installation of Direct Vent System ......12 Direct Vent - Horizontal Terminations ......13 Replacement/Spare Parts List ........
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies NOTE: Masport units are constantly being im- each P33R-1 Zero Clearance Room Sealed Gas proved. Check the label on the unit and if there Fireplace. We have printed a copy of the con- is a difference, the label on the unit is the correct tents here for your review.
  • Page 5: Installation

    INSTRUCTIONS THE APPLIANCE. called to inspect this appliance an- nually. Make it a practice to have all The P33R-NG1 or P33R-LPG1 Room Sealed CLOTHING OR OTHER FLAMMA- of your gas appliances checked an- Fireplace must be installed in accordance with BLE MATERIAL SHOULD NOT BE nually.
  • Page 6: Installation Checklist

    Clearances for Bay or Flush Front Diagram 1 WARNING Fire hazard is an extreme risk if Flat on Wall these clearances are not adhered Flat on Wall Corner Recessed into Wall/Alcove Corner Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 7: Combustible Mantel Clearances

    Ensure that both the material and finished surface (paint) are heat resistant (min. 85 C) or material may distort and paint may discolor. MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram below: Maximum 1-1/2" projection at 2" minimum clearance. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 8: Framing And Finishing

    1-1/2" (38mm) clear- ance from the vent to combustible materials for flex. NOTE: If this is an outside corner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 9: Unit Assembly Prior To Installation

    A, B, or C depending on your facing depth. 2) Use the same screw hole position for the Side Nailing Strips as was used for the Top Facing Support. Attach each side nailing strip using 3 screws. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 10: Exterior Flue Termination Locations

    (IV)A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 11: Flueing Introduction

    Warnock Hersey. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram on page 10. Masport Direct Vent (Flex) System Termination Kit (Part # 946-513) includes all the parts needed to install the P33R-1 with a maximum run of 2 feet.
  • Page 12: Installation Of Direct Vent System

    INSTALLATION INSTALLATION PROCEDURES for Masport Direct Vent System (Flex) 1) Locate the unit in the framing, rough in the *If this is an outside corner, the minimum distance between the flue and the gas (preferably on the right side of the unit) outside corner is 6"...
  • Page 13: Direct Vent - Horizontal Terminations

    INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS Masport Direct Vent for Horizontal Terminations (LPG & NG) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using two 90 elbows (two 45 elbows equal one 90 elbow). A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes.
  • Page 14: Flueing Arrangements Vertical Terminations

    The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations , using three 90 elbows (two 45 elbows equal one 90 elbow). • Flue must be supported at offsets • Maintain a 1-1/4" (40mm) clearance to combustibles Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 15: Flueing - Horizontal Installations

    7"(178mm) tained (Diagram 3). Install the termination diameter (7-1/2"(191mm) dia. for flex) hole cap. is acceptable. Diagram 4 Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 16: Flueing - Vertical Installations

    Note: Apply sealant "Mill-Pac" to inner 601 or NZS 5261:2003 pipe and high temperature sili- cone sealant to outer pipe on every Note: Any closets or storage spaces, which twist-lock joint. the flue passes through must be en- closed. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 17: Pilot Adjustment

    Note: If you have an incorrect flame pressure ports on the valve. - LPG 22 mj pattern, contact your Masport dealer for Min. Input Rating further instructions. 11 mj 1) Make sure the valve is in the "OFF" position. -LPG 11 mj 2) Loosen the "IN"...
  • Page 18: Conversion To Lpg

    18) Check operation of flame control. the new screws (E) supplied with the kit. Tighten screws securely. 19) Check for proper flame appearance and glow on logs. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 19: Optional Brick Panels

    5) Slide the Top Brick Panel into position and A) 02-57 slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and A) 02-57 tighten down the screws. B) 02-61 2nd Grate Tab Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 20 7) Position Log E) 02-59 across the cutouts in Logs B) 02-61 and C) 02-60. The notch in the bottom right end fitting against the 5th grate tab. B) 02-61 5th Grate Tab A) 02-57 D) 02-58 B) 02-61 Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 21: Flush Door - Standard

    Attach the round magnets to the back of the top trim piece and to the bottom trim piece, then attach trim to the top and bottom of Flush door. Note: Top and bottom louvres are different. Diagram 1 Diagram 2 Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 22: Remote Control (Optional)

    Option 2: WALL THERMOSTAT Wire Table REMOTE CONTROL Use the Masport Remote Control Kit approved Recommended Maximum Lead A wall thermostat may be installed if desired, for this unit. Use of other systems may void your Length (Two-Wire) When Using Wall connect the wires as per the wiring diagram.
  • Page 23: Wiring Diagram

    Do not cut or remove the grounding prong improper and dangerous touch any hot surfaces and are away from this plug. operation. from sharp edges. NOTE: Switch must be in "OFF" position to operate remote. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 24: Lighting Plate Instructions

    1) Turn OFF the flame switch. 2) Push in gas control knob slightly and turn to "OFF" position. You may shut off the pilot during prolonged non use periods to conserve fuel. DO NOT REMOVE THIS INSTRUCTION PLATE 918-253 Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 25: Operating Instructions

    NOT covered under war- become very difficult to remove. Use a non-abrasive cleaner and NEVER clean ranty. the glass while it is hot. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 26: Normal Operating Sounds Of Gas Appliances

    This is not supports such as Wall Straps, or plumbers' slightly different rates which can cause "tick- unique to Masport gas fires. If the surface tape for rigidity. ing" and "cracking" sounds. You should also...
  • Page 27: Log Replacement

    The position of these logs must be as shown in the diagrams under Log Installation. Your Masport stove is supplied with high tem- perature, 5 mm Neoceram ceramic glass that Note: Improper positioning of logs may will withstand the highest heat that your unit will create carbon build-up and will produce.
  • Page 28: Removing Valve

    17) Close the door and replace the louvres. 18) Fire up the unit again and check for proper flame appearance and glow on logs. Valve Tray Assembly screws Diagram 2: Rear Log Stand & Valve Tray Assembly Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 29: Parts List

    14) 948-115 Door Extension Spring 918-046 Manual 431-969 Conversion Kit - NG to LPG 15) 948-247 Spring Lever *Not available as a replacement part. 17) * Wire Holder Clip 19) 430-044 Bottom Support Bracket Left/Right Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 30 Air Deflector-Right (Nat. Gas) 910-386 Thermocouple 910-341 Thermopile 902-250 Rear Log 902-251 Rear Left Log 902-253 Front Left Cross Log 902-252 Front Right Cross Log 902-254 Middle Cross Log *Not available as a replacement part. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 31 Flush Louvre Assy-Top 134) * Flush Louvre Assy-Btm 135) 940-088/P Glass (Flush) 137) 904-691 556291 U-Clip 139) 936-155 556283 Glass Gasket (Tadpole) 140) 948-042 556301 Spring Hinge - Black *Not available as a replacement part. Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 32 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 33 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 34 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Masport P33R-1 Room Sealed Gas Fireplace...
  • Page 35: Warranty

    Express Warranty as per the time condition outlined. How You Obtain Warranty Service: If an approved Masport Gas Service Agent is requested to attend on a Provide proof of the date of purchase. Should the need for a warranty...
  • Page 36 Printed in Canada © Copyright 2004, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

P33r-lpg1

Table of Contents