Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been
tested in accordance with AG 103,
NZS 5262 and have been certified by
the Australian Gas Association for
installation and operation as
described in these Installation and
Operating Instructions.
Your unit should be serviced
annually by an authorised service
person.
Zero Clearance Room
Sealed Gas Fireplace
STYLE
See Thru
P121-NG
Left Corner
P121LC-NG
Right Corner P121RC-NG
Pier
P131-NG
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult an authorized installer, serv-
ice agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flamma-
ble vapours and liquids in the vicinity of this
or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
Australia
P.O. Box 533
Braeside, Victoria
3195
918-180b
MODEL
P121-LPG
P121LC-LPG
P121RC-LPG
P131-LPG
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
New Zealand
1-37 Mt
Wellington Hwy.Panmure,
P.O. Box 14349
Auckland 6.
01/20/04

Advertisement

Table of Contents
loading

Summary of Contents for Masport P121-NG

  • Page 1 Owners & Installation Zero Clearance Room Sealed Gas Fireplace STYLE MODEL See Thru P121-NG P121-LPG Left Corner P121LC-NG P121LC-LPG Right Corner P121RC-NG P121RC-LPG Pier P131-NG P131-LPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera-...
  • Page 2 Gas Association for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Masport Fireplace. IMPORTANT:...
  • Page 3: Table Of Contents

    Log Set Installation ........... 23 Glass Door Removal ..........25 Finishing Trim ............25 Louvers and Grills ............25 Remote Control (optional) .......... 26 Wall Thermostat (optional) ........26 Wiring Diagram ............27 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 4: Safety Label

    We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louvre is open. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 5: Installation

    CAUTION: Any alteration to the product fuels (wood, paper, cardboard, coal, etc.) that causes sooting or carboning that be used in this appliance. results in damage is not the responsi- bility of the manufacturer. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 6: Specifications

    INSTALLATION SPECIFICATIONS P121 - See Thru Note: These units are non-load bearing. P131 - Pier Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 7 INSTALLATION P121LC - Left Corner Unit Note: These units are non-load bearing. P121RC - Right Corner Unit Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 8: Locating Your Gas Fireplace

    Have a C) P121LC - Left Corner authorized inspector, dealer, or installer review your plans before installation. Note: For Exterior Flue Termination Locations see page 12. D) P121RC - Right Corner Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 9: Clearances

    Caution: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. * If the 3" (76mm) metal extension trim is removed it must be replaced with a 8" (203mm) non-combustible material. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 10: Framing And Finishing

    Flue Clear- ances, page 9. P121LC - Corner Unit P121 - See Thru P131 - Pier P121RC - Corner Unit Note: These units are non-load bearing. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 11: Facing And Finishing Requirements

    Each direct flue gas appliance must use it's own separate flue system. Common flue systems 3) Attach the standoff securely to the top with are prohibited. 4 screws per standoff (on opposite cor- ners). Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 12: Exterior Flue Termination Locations

    (IV)A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 13: Flueing: Direct Vent System (Flex)

    Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 12. Masport Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121/P121LC/P121RC/ P131 with a maximum run of 2 feet.
  • Page 14: Flueing Arrangements Horizontal Terminations

    With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 1 Diagram 2 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 15 With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 4 Diagram 6 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 16: Vertical Terminations

    With the above options, maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 7 Diagram 8 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 17 With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal. Please note minimum 1 foot between 90 elbows is required. Diagram 11 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 18: Flueing - Horizontal Installations

    If the wall being penetrated is con- structed of non-combustible material, i.e. masonry block or concrete, a 7"(178mm) dia. (7-1/2"(191mm) dia. for flex) hole is acceptable. Diagram 3 Diagram 1 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 19: Flueing - Vertical Termination

    Continue to add pipe sections through the flashing until the height of the flue cap meets the minimum height requirements specified in Diagram 5 or local codes. Note that for steep Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 20: System (Flex)

    8"(35mm) and fasten with the 3 screws. NOTE: Horizontal sections must be sup- ported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner). Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 21: Conversion To Lpg

    (E) supplied with the kit. 19) Check for proper flame appearance and Tighten screws securely. glow on logs. 13) Reverse steps 4) to 1). Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 22: System Data

    Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 23: Log Set Installation

    02-81 02-79 02-82 02-80 end of the log into the grate post. 02-80 Tab on Burner Grate Post 02-80 02-82 02-79 02-81 Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 24 Log onto the second grate post from the left. Ensure that the log fits into a pin that is on Log 02-79. 02-81 02-81 02-82 02-79 Place Log 02-82 onto pin. Grate Post Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 25: Glass Door Removal

    3) P131 & P121LC/P121RC Corner Model: Push trim tight Remove the 6 screws that secure the The Top and Bottom Side Louver or Grill is against magnet. glass door and repeat step 2. installed the same way. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 26: Remote Control (Optional)

    4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 27: Wiring Diagram

    CAUTION: Label all wires Terminal Block Location prior to disconnection when servicing controls. Wiring er- rors can cause improper and dangerous operation. Terminal Block Remove cover to access Terminal Block Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 28: Operating Instructions

    4) Turn ON the flame switch. yellow open up the air shutter, if it is too blue close the air shutter. 10mm open 10mm open NOTE: This adjustment is only to be made by an authorised person. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 29: Lighting Plate Instructions

    These will appear as rust spots or streaks, DO NOT REMOVE THIS INSTRUCTION PLATE and in extreme cases, holes. These com- 918-253 ponents should be replaced immediately. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 30: Log Replacement

    Clean any finger- prints off before turning the unit on. 7) Slide the burner assembly away from the orifice and lift out. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 31: Installing Valve

    INSTALLING VALVE combustion conditions can cause deterioration of the paint finish. This is not unique to Masport Gas Fires. 1) Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided.
  • Page 32: Parts List

    360-926 Louver Front - Black/Brass (set) 24) * Relief Door Assembly 32) 902-296 Brick Panel - Base - Front 33) 902-297 Brick Panel - Base - Side 34) 902-298 Brick Panel - Side Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 33 32) 902-296 Brick Panel - Base - Side 360-936 Louver Side - Black/Steel (set) 360-938 Louver Side - Black/Brass (set) 33) 902-297 Brick Panel - Base - Front 34) 902-298 Brick Panel - Side Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 34 33) 902-297 Brick Panel - Base - Front 173) 360-932 Louver Side - Black (set) 34) 902-298 Brick Panel - Side 360-934 Louver Side - Black/Gold (set) 360-936 Louver Side - Black/Steel (set) 360-938 Louver Side - Black/Brass (set) Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 35 33) 902-297 Brick Panel - Base - Front 360-934 Louver Side - Black/Gold (set) 34) 902-298 Brick Panel - Side 360-936 Louver Side - Black/Steel (set) 35) 902-300 Brick Panel - Front 360-938 Louver Side - Black/Brass (set) Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 36 Orifice #31 - NG 936-170 Orifice Gasket 83) 910-073 Spark Generator Battery Holder 84) 910-074 Spark Generator Switch c/w Wire 90) 910-386 Thermocouple 91) 910-341 Thermopile *Not available as a replacement part. Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 37 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 38 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Masport P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace...
  • Page 39: Warranty

    WARRANTY THE MASPORT EXPRESS WARRANTY All new Masport Gas appliances are warranted, subject to the This Express Warranty Does Not Cover: following conditions, to be free from defects in material or 1. Defects, malfunctions or failures caused by incorrect workmanship under normal use. The Express Warranty on all...
  • Page 40 Printed in Canada © Copyright 2004, FPI Fireplace Products International Ltd. All rights reserved.

Table of Contents