Installation Instructions; System Data Table; Gas Connection - Masport New York Owners & Installation

Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

System Data
For 0 to 610 metres altitude*
Burner Inlet Orifice Sizes:
Burner Inlet Orifice Sizes:
Burner Inlet Orifice Sizes:
Burner Inlet Orifice Sizes:
Burner Inlet Orifice Sizes:
Natural Gas Propane
Rear Burner
n/a
Front Burner
#31(3.0mm) #56(1.15mm)
Input Rating
Input Rating - Natural Gas
Input Rating
Input Rating
Input Rating
- Propane
Supply Pressure:
Supply Pressure:
Supply Pressure:
Supply Pressure:
Supply Pressure:
Natural Gas
min.
Propane
min.
Manifold Pressure
Manifold Pressure
Manifold Pressure
Manifold Pressure
Manifold Pressure
Natural Gas
Propane

GAS CONNECTION

For minimum and maximum supply pressure see the System
Data table on page 8.
Note: Prior to any pressure testing of the gas supply
piping system that exceeds test pressures of 1/2
psig (3.45 kPa), this appliance and its individual
shut-off valve must be disconnected from the
piping system. If test pressures equal to or less
than 1/2 psig (3.45 kPa) are used then this appli-
ance must be isolated from the piping system by
closing its individual manual shut-off valve during
the testing.
GAS CONNECTION WARNING:
Only persons licensed to work with gas piping may make
the necessary gas connections to this appliance.
8
#54(1.4mm)
40 mj
39 mj
1.13 kPa
2.75 kPa
.85 kPa
2.55 kPa
Valve Access: Loosen and
remove the wingnuts on the
both sides of the bottom lou-
vre and then remove the lou-
vre.
1)
If the appliance is to be installed into an existing chimney
system, thoroughly clean the masonry fireplace and have
the chimney swept.
2)
The gas connection is a 1/2" BSP male pipe on the rear
left side of the unit. The gas line can be rigid pipe or to
make installation easier use a listed flexible connector
and manual shut-off valve if allowed by local building
codes. A 1/2" gas supply pipe must be brought near this
inlet hole.
3)
Locate the center point where the flue will pass through
the chimney above the appliance. Move the appliance
into the exact location where it is to be installed. Ensure
that the Inbuilt is level.
4)
The gas control valve is provided with two "IN" and "OUT"
pressure taps, and are easily accessible for a test gauge
connection (see diagram on page 10).
5)
Once the gas has been connected ensure that the pilot
valve is in line with burner.
CAUTION: If the door is removed or opened for servicing,
it must be replaced and closed prior to operating the
appliance. The glass must be fixed in the door when
operating.
Masport I43 NEW YORK / ULTIMATE Gas Inbuilt Fireplace