FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-FLUE DIRECT FLUE GS SYSTEM and
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45
equal one 90
o
elbow).
Note: Must use optional flue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)
A flue guard should be used whenever the termination is
lower than the specified minimum or as per local codes.
Note: Masport Direct Flue System (Flex) is only
approved for horizontal terminations.
Maintain clearances to combustibles.
Horizontal flue must be supported every 3 feet.
Firestops are required at each floor level and whenever passing through a wall.
18
MASPORT DIRECT FLUE SYSTEM (FLEX)
(ULPG with NG/LPG Burner)
IMPORTANT NOTE
If the Burner is not a ULPG Burner, a
minimum flue rise of 1362mm (total height
from the floor) MUST BE adhered to.
o
and one 90
o
elbow (two 45
o
Masport PG33 Gas Inbuilt
elbows