DRAFT DIVERTER CONNECTION

1)
Attach the flue to the flue collar on the detachable draft
diverter. The flue collar of the appliance will fit inside a
standard 100mm flue and may be fastened directly to the
flue by sheet metal screw.
2)
Before pushing the appliance into position inside the
fireplace, align the draft diverter with the guides on the
inbuilt top and push forward. While pushing the unit back
into place keep pulling the draft diverter forward until the
screw hole in the spill tube-rear aligns with the screw hole
in the spill tube-front. (If screw holes do not line up then
draft diverter is not positioned correctly.) Secure the two
spill tubes with a screw.
Note: Final gas connection should be after unit is in place
to avoid damage to line when pushing the unit into
position.
Masport I43 NEW YORK / ULTIMATE Gas Inbuilt Fireplace
INSTALLATION REQUIREMENTS
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIM-
NEY FLUE SERVING A SEPARATE SOLID FUEL BURNING
APPLIANCE.
This appliance is designed to attach to a 100mm diameter flue
or approved aluminum flex liner running the full length of the
chimney. A minimum flue height of 3.6 m is recommended. B-
Vent must be supported by a flue support - supplied by flue
manufacturer. There must be at least 0.9 m of chimney above
the roof level.
Stack the pipe onto your finish support to a minimum height
of 0.9m above the roof penetration, or 0.6m above any point
within 3m measured horizontally. B-Vent chimneys require a
25mm clearance to combustibles.
The Masport Inbuilt incorporates its own internal draft diverter,
so no additional external draft diverter is required. Periodically
check that the flue is unrestricted and an adequate draft is
present when the unit is in operation. (See page 11 for spillage
test.)
Before installing flue system ensure that the damper plate is
locked into the open position and secure to prevent the damper
plate from falling down and crushing the liner.