12.
12.1
Carefully lift the casting. Place it against the fireplace front surface so that the retaining strip at the back of the casting
is above the two upper retaining brackets at the top of the convection box. Lower the casting making sure that the rear
retaining strip locates fully over the retaining brackets on the convection box (See figure 19).
12.3
Slide the front casting/surround sideways, if necessary, to align the bottom fixing holes with those in the convection
box. Fix the bottom of the casting/surround to the convection box with two screws (See figure 20).
Fig. 19 "Adorn" front casting top location
13.1
Locate the guard bottom wires over the brass ash lip. Hold the top springs down. Swing the guard back. Release the
springs so that they locate behind the canopy (See figures 22 and 23).
Figure 21 Fitting "Adorn" safety guard

#923 ADORN CAST FRONT INSTALLATION

13. ADORN SAFETY GUARD FITTING

Fig. 20 "Adorn" Front casting bottom fixing
Fig 22
14 of 19