This unit is equipped with a vent safety switch, located on the right side of the draft hood, which will shut the burner off if
the vent is not functioning properly. Use a match or a source of smoke at the front of the draft channel to check direction of
flow in the vent. Access to the vent switch for servicing is shown below.
The fret retainer brackets are designed to maintain the required space in front of the window to allow the window to
move and relieve during a hard start. It is very important to ensure the area in front of the window is kept clear
at all times.
Install the Fret Retainer Brackets
1. Release the two thumbscrews on the each side of
the fireplace.
2. Fit the slotted holes in the fret retainers over the
thumbscrews and push the retainers down.
3. Tighten the thumbscrews.
Install the Cast Iron Fret
1. Adjust the screw heads on the back of the fret to the
thickness of the retainer bracket.
2. Drop the fret into place while guiding the screw
heads into the slots in the brackets.
3. Clip the ash pan cover onto the fret.
16

Vent Check

To check vent action,
hold a match or
source of smoke in
front of Draft Channel
(smoke should be drawn
inward)
Draft Channel
Vent Check

Cast Iron Fret Installation

Draft Channel
Bracket secured
by 2 screws
RH side of fireplace
Vent Safety Switch Location
Vent Switch
Vent Switch
Bracket
Slip Fret Retainer
over thumbscrews
and tighten screws
Drop Fret with Bolt
into Slotted Retainer
(fret adjusts up or
down to suit)