Radyne DMD2401 Operation Manual page 126

Table of Contents

Advertisement

DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem
Opcode: <2A08h>
<1>
Convolutional
Decoder
Opcode: <2A09h>
<1>
Differential
Decoder
Opcode: <2A0Ah>
<1>
Reed-Solomon
<1>
Reed-Solomon N
<1>
Reed-Solomon K
<1>
Reed-Solomon T
<1>
RS Interleaver
Depth
Opcode: <2A0Dh>
<1>
Descrambler
Control
Opcode: <2A0Eh>
<1>
Descrambler
Type
Opcode: <2A0Fh>
<1>
Spectrum
Opcode: <2A11h>
<1>
Buffer Clock
Opcode: <2A12h>
<1>
Buffer Clock
Polarity
Opcode: <2A13h>
<1>
Insert Mode
TM065 - Rev. 3.3
Command a Demodulator's Convolutional Decoder
0 = None
1 = Viterbi 1/2 Rate
3 = Viterbi 3/4 Rate
5 = Viterbi 7/8 Rate
7 = Sequential 1/2 Rate
9 = Sequential 3/4 Rate
11 = Sequential 7/8 Rate
14 = Trellis 2/3
20 = TPC 0.7932D
21 = TPC 0.4953D
Command a Demodulator's Differential Decoder
0 = Off, 1 = On
Command a Demodulator's Reed-Solomon
0 = Disable, 1 = Enable
Unsigned Binary
Unsigned Binary
Note: Always set to Zero; as the T value is calculated
from N and K.
Unsigned Binary, 4 or 8
Command a Demodulator's Descrambler Control
0 = Disable, 1 = Enable
Command a Demodulator's Descrambler Type
0 = None
1 = IBS Scrm.
2 = V35_IESS
3 = V35_CCITT
4 = V35_EFDATA
7 = Reed-Solomon Scrm.
8 = V35_EFRS
Command a Demodulator's Spectrum
0 = Normal, 1 = Inverted
Command a Demodulator's Buffer Clock
0 = External, 1 = Internal, 2 = EXC, 3 = RX SAT
Command a Demodulator's Buffer Clock Polarity
0 = Normal, 1 = Inverted
Command a Demodulator's Insert Mode
0 = Disable
1 = T1-D4
User Interfaces
4-87

Advertisement

Table of Contents
loading

Table of Contents