DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem
Encoder
Opcode: <2609h>
<1>
Carrier Control
Opcode: <260Ah>
<1>
Carrier Selection
Opcode: <260Bh>
<1>
Clock Control
Opcode: <260Ch>
<1>
Clock Polarity
Opcode: <260Dh>
<1>
SCT Source
Opcode: <260Eh>
<1>
Mode
Opcode: <260Fh>
<2>
Transmit Power
Level
TM065 - Rev. 3.3
Command a Modulator's Carrier Control
0 = Off, 1 = On, 2 = Auto, 3 = VSat, 4 = RTS
Command a Modulator's Carrier Selection
0 = Normal, 1 = CW, 2 = Dual, 3 = Offset
Command a Modulator's Clock Control
0 = Internal (SCT), 1 = External (SCTE)
Command a Modulator's Clock Polarity
0 = Normal, 1 = Inverted, 2 = Auto
Command a Modulator's SCT Source
0 = Internal, 1 = SCR, 2 = Ext. BNC
Command a Modulator's Drop Mode
0 = Disable
1 = T1-D4
2 = T1-ESF
3 = PCM-30
4 = PCM-30C
5 = PCM-31
6 = PCM-31C
7 = T1-SLC96
Command a Modulator's Output Level
Signed Binary Value. -50 to -300 (-5.0 to -30.0 dBm), Implied
Decimal Point