Radyne DMD2401 Operation Manual page 100

Table of Contents

Advertisement

DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem
<1>
G.703 Interface
Type
<1>
BPSK Symbol
Pairing
<1>
AUPC Enable
<2>
AUPC Eb/No
<2>
AUPC Minimum
Power Limit
<2>
AUPC Maximum
Power Limit
TM065 - Rev. 3.3
0 = G703T1AMI
1 = G703T1B8ZS
2 = G703BE1
3 = G703UE1
Note: The following byte applies to all DMD2401 modems,
regardless of interface type.
0 = Normal, 1 = Swapped
Note: The following byte applies only if an Asynchronous
Interface Card, or an IDR OR IBS Interface Card is
installed, AND the AUPC option is also installed. If not,
set to zero.
Note: AUPC minimum power level < AUPC default power
level < AUPC max. power level.
0 = Disabled, 1 = Enabled
Note: The following two bytes apply only if an
Asynchronous Interface Card, or an IDR OR IBS Interface
Card is installed, AND the AUPC option is also installed.
If not, set to zero.
Note: AUPC minimum power level < AUPC default power
level < AUPC max. power level.
Unsigned Binary, 1 Decimal Point Implied
Note: The following two bytes apply only if an
Asynchronous Interface Card, or an IDR OR IBS Interface
Card is installed, AND the AUPC option is also installed.
If not, set to zero.
Note: AUPC minimum power level < AUPC default power
level < AUPC max. power level.
Signed Value, –50 to –300 (–5.0 to –30 dBm), Implied Decimal
Point
Note: The following two bytes apply only if an
Asynchronous Interface Card, or an IDR OR IBS Interface
Card is installed, AND the AUPC option is also installed.
If not, set to zero.
Note: AUPC minimum power level < AUPC default power
level < AUPC max. power level.
Signed value, –50 to –300 (–5.0 to –30 dBm), Implied Decimal
Point
Note: The following two bytes apply only if an
Asynchronous Interface Card, or an IDR OR IBS Interface
Card is installed, AND the AUPC option is also installed.
If not, set to zero.