User Interfaces
<1>
BER Measure
Period
<24>
Rx Circuit ID
<1>
Rx Terrestrial
Loopback
<1>
Rx Baseband
Loopback
<1>
Rx IF Loopback
<1>
Reserved
<1>
Data Invert
<1>
Async Framing
<1>
Async Baud Rate
<1>
Async Port Type
<1>
Async Terrestrial
Interface Type
<1>
Multiprotocol
Interface Card
Interface Type
4-70
DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem
Unsigned Binary Number of Bits in Measurement Period, in
Powers of Ten (ex: 6 = 10
24 ASCII Characters
0 = Disabled, 1 = Enabled
0 = Disabled, 1 = Enabled
0 = Disabled, 1 = Enabled
Ignore
0 = Normal, 1 = Invert
Note: The following byte applies only if an
Asynchronous, IDR or IBS Interface is installed. If not,
ignore.
0 = No Framing, 1 = 1/16 IBS, 2 = 1/16 Async, 3 = 96 Kbit IDR
Note: The following byte applies only if an asynchronous
interface card is installed. If not, ignore.
0 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 50
6 = 110
7 = 300
8 = 600
Note: The following byte applies only if an asynchronous
interface card is installed. If not, ignore.
0 = RS-232, 1 = RS-485
Note: The following byte applies only if an asynchronous
interface card is installed. If not, ignore.
0 = RS-422, 1 = V.35, 2 = RS-232
Note: The following byte applies only if a synchronous
multiprotocol interface card is installed. If not, ignore.
0 = V.35, 1 = RS-422, 2 = RS-232
Note: The following byte applies only if a symmetric
G.703 interface card is installed. If not, ignore.