Advanced System Management error codes

Code/explanation
9100-xxx-xxx-xxx (SAL/EFI failed to communicate with
ASM.)
9101-000-000-000 (DMC Self Test failed to complete.)
9102-000-000-000 (DMC Self Test failed update.)
9103-000-000-000 (DMC Self Test failed ROM.)
9104-000-000-000 (DMC Self Test failed RAM.)
9105-004-000-000 (ISMP indicates I2C errors on bus A0.) 1. I/O board
9105-004-001-000 (ISMP indicates I2C errors on bus A1.) 1. VRMs and microprocessors installed in midplane
9105-004-002-000 (ISMP indicates I2C errors on bus A2.) 1. Memory board
FRU/action
1. Run ASM Restart Test to restart ASM.
2. Rerun diagnostic test.
3. Correct other error conditions, including other failed
system management tests and items logged in
Remote Supervisor adapter system-error log, and
retry.
4. Disconnect all server and option power cords from
server, wait 30 seconds, reconnect, and retry.
5. Remote Supervisor Adapter.
6. I/O board.
1. Disconnect all server and option power cords
from server, wait 30 seconds, reconnect, and
retry.
2. Update the ISMP on the xSeries 455 node and RXE
with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test
on xSeries 455 node.
1. Disconnect all server and option power cords
from server, wait 30 seconds, reconnect, and
retry.
2. Update the ISMP on the xSeries 455 node and RXE
with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test
on xSeries 455 node.
1. Disconnect all server and option power cords
from server, wait 30 seconds, reconnect, and
retry.
2. Update the ISMP on the xSeries 455 node and RXE
with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test
on xSeries 455 node.
1. Disconnect all server and option power cords
from server, wait 30 seconds, reconnect, and
retry.
2. Update the ISMP on the xSeries 455 node and RXE
with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test
on xSeries 455 node.
2. Midplane board
board
2. Midplane board
2. Midplane board
Chapter 6. Symptom-to-FRU index