Code/explanation
9204-092-094-xxx, where xxx is 000-020
(Insufficient data transfer.)
9204-092-094-xxx, where xxx is 041-054
(Insufficient data transfer.)
9204-091-094-016
(Insufficient data transfer.)
9216-092-094-xxx
(Receive error.)
9220-092-094-xxx, where xxx is 000-020
(Transmit error.)
9220-092-094-xxx, where xxx is 041, 045,
049, 053
(Transmit error.)
9220-092-094-xxx, where xxx is 042, 046,
050, 054
(Transmit error.)
9220-092-094-xxx, where xxx is 056-063
(Transmit error.)
9228-092-094-xxx
(No cable detected.)
9232-092-094-xxx
(Port is not initialized.)
9236-092-094-xxx
(Port is disabled.)
9244-092-094-xxx, where xxx is 041-063
(Test is skipped.)
9256-092-094-xxx, where xxx is 000-020
(Deskew error.)
192
IBM xSeries 455 Type 8855: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Scalability cable on that port
2. Processor board attached to that cable
3. Processor board attach to far end of cable
1. RXE cable on that port
2. RXE expansion board to which cable is connected (Side A or Side
B)
3. I/O board to which cable is connected
4. Midplane board
1. Side B card in RXE100
2. Side A card in RXE100
1. Restart the server. This usually means that an RXE cable has
been attached after SAL/EFI has run.
2. Cable on that port
1. Scalability cable on that port
2. Processor board attached to that cable
3. Processor board attached to far end of cable
1. RXE cable A
2. RXE expansion board to which cable is connected (Side A or Side
B)
3. I/O board
1. RXE cable B
2. RXE expansion board to which cable is connected (Side A or Side
B)
3. Midplane board
1. Side A card in RXE100 (if xxx is 056, 057, 060, 061)
2. Side B card in RXE100 (if xxx is 058, 059, 062, 063)
1. Attach a scalability or RXE cable to the port being tested.
2. Power on system at other end of cable.
1. Attach a scalability or RXE cable to the port being tested.
2. Power on system at other end of cable.
Other end of this connection is not accessible. For example, when
testing "RXE-100, Side B, Port A and Side A" is not part of this
system, then this test will fail with "Port is disabled."
1. Select another port. Running this test might restart the server. Try
testing the port on the other end of the cable.
2. Select another port. Running this test on this port might restart the
system. Try testing the port an the other end of the cable.
1. Scalability cable on that port
2. Processor board attached to that cable
3. Processor board attached to far end of cable
4. RXE cable A
5. RXE expansion board to which cable is connected (Side A or Side
B)
6. I/O board