Error message/symptom
9909 (This node unable to set merge state on node x,
check scalability cable connections, W/R[y/z])
9910 (Invalid SAL version on node x, reflash SAL on all
nodes.)
9911 (SAL version mismatch between node x and node y,
reflash SAL on all nodes.)
9912 (Scalability cable fault on port x, check cable,
performance degraded.)
9913 (Partition ID mismatch between node x and node y,
check cache settings in Configuration/Setup Utility
program.)
9914 (L3 cache state mismatch between node x and
node y, check cache settings in Configuration/Setup Utility
program.)
9915 (This node expected to find node x through port y,
instead found node z, check scalability cable
connections.)
9916 (Partition configuration invalid, check partition
settings and scalability cable connections.)
9917 (Node x is in standalone mode, this node will reset
and boot standalone.)
9918 (Partition boot failed three times, booting to
Configuration/Setup Utility program in standalone mode,
examine error log for each partition node.)
FRU/action
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
3. Reseat scalability cables.
4. Replace scalability cable connected between this
node and node x.
5. Replace processor board.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
3. Update SAL/EFI on all nodes in partition.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
3. Update SAL/EFI on all nodes in partition.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
3. Reseat scalability cables.
4. Replace scalability cable connected to port x.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
1. Check scalability cable configuration.
2. Make sure that cache settings in Configuration/Setup
Utility program match on all nodes.
3. Update SAL/EFI on all nodes in partition.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
1. Check scalability cable configuration.
2. Verify partition settings in Configuration/Setup Utility
program.
3. Examine system-error log for cause of POST failures.