Martin Alien 05 User Manual page 10

Hide thumbs Also See for Alien 05:
Table of Contents

Advertisement

This enables remote control of power on and off of the Alien 05s via either
an Oracle controller or DMX control device, that is attached to the 05 Driver
(when the intensity channel is set at less than 10% the relay closes and the
luminaires switch off.
Mains
80-250V AC
50/60 Hz
Warning
Do not draw more than 10 amps through the 05 Driver mains
relay. If the mains supply is under 200 volts and the number of
connected Alien 05's is over 15, check that the combined
current draw of all transformers will not exceed 10 A.
R e m o t e l y d i m m a b l e p o w e r -s u p p l y c o n f i g u r a t i o n
Note:
This configuration does not apply for Alien 05 Eyeball models
as they draw their power via the transformer that is built into
the Halo Recessed fixture housing. These transformers are not
dimmable.
In this configuration, one or more dimmable transformers supply 12V power
to one or more Alien 05s, and are connected to the 0-10V analog output on
the 05 Driver. The transformer can be powered through the 10A mains relay
(if remote power on/off is required), or directly from the mains supply.
Mains
80-250V AC
10
80-250V AC
50/60 Hz
50/60 Hz
80-250V AC
50/60 Hz
Analog 0-10V
Configuring an Alien 05 system
Max
45 cm
12V AC
Max
45 cm
12V AC

Advertisement