LIGHTING INSTRUCTIONS

STOP! Read the safety information on Warning plates.
1.
Make sure manual shutoff valve is fully open, installed two AAA batteries in the transmitter.
2.
Open the door of the heater, push in control knob slightly and clockwise
ON or OFF position, adjust it to REMOTE position.
3.
Wait five (5) minutes to clear out any gas. Then smell gas around heater and near floor. If you smell gas, STOP!
Follow "B" in the safety information on Warnings plate.
If you don't smell gas, go to the next step.
4.
Push in the control knob slightly and turn counterclockwise
NOTE: The first time the heater is operated after connecting the gas supply, the control knob should be depressed
for about thirty(30) seconds. This will allow gas to bleed from the gas system.
5.
With the control knob pressed in, push down and released the ignitor button. This will light the pilot. If needed, keep
pressing ignitor button until pilot lights.
6.
Keep the control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat step 5,6 and 7.
7.
Rotate counterclockwise
Note: You may be operating this heater for the first time after hooking up to gas supply. If so, the lighting will be
lasted for 30 seconds. This will allow air to bleed from the gas system.
Note: If you miss your transmitter, adjust switch to ON position to light burner. from the gas system.
TO TURN OFF GAS TO APPLIANCE
Shutting off heater
1. Press the
OFF
2. Turn gas control knob clockwise
to ON position, then press button to light burner.
button to let pilot stay.
to OFF position to shut off burner.
Figure 23 Ignitor switch location
to " PILOT " and depress for five (5) seconds.
21
to the OFF position. If the switch is on

Hide quick links: