LIGHTING INSTRUCTIONS

For FBD400T-C/O/CG
Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.
1.
STOP! Read the safety information on page 17.
2.
Warning: You must operate this heater with the screen in place. Make sure screen is installed before running heater.
3.
Turn control knob clockwise to the OFF position, see Figure 16.
4.
Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near floor. If you smell gas,
STOP! Follow "B" in the safety information on Warnings plate. If you don't smell gas, go to the next step.
5.
Turn control knob counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds.
Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. If control knob does not
pop up when released, contact a qualified service person or gas supplier for repairs.
6.
With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to
the rear of the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit,
contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.
7.
Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If
pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before
lighting pilot again.
8.
Warning Make sure while the input gas type is NG, pilot burner NG ignites; while the input type is LP, pilot
burner LP ignites. Note: If you find anything abnormal in this step, repeat steps 2 through 8.
9.
Turn control knob counterclockwise to the desired heating level. The main burner should light. Set control knob
to any heat level between HI and LO (5 –1).

THERMOSTATIC CONTROL OPERATION

Note: The thermostat sensing bulb measures the temperature depending on housing construction, the thermostatic
control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off.
The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature.
If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.
The control knob can be set to any comfort level between HIGH (5) and LOW (1).