IBM eServer 445 xSeries Hardware Maintenance Manual And Troubleshooting Manual page 232

Type 8870
Hide thumbs Also See for eServer 445 xSeries:
Table of Contents

Advertisement

Note: See Chapter 8, "Parts listing, Type 8870," on page 249 to determine which components are replaceable
by the customer, and which components should be replaced by an IBM field service technician.
Error code/symptom
201-XXX-Y34 (Multiple DIMM failure in
Port 2 Bank 4; see "Removing and
replacing DIMMs" on page 108)
Note: Y = SMP Board [0=Bottom SMP
Board; 1=Top SMP Board]
202-xxx-00n (Failed System Cache test)
203-xxx-xxx (Failed External Cache test)
204-198-0xx (Test Aborted)
Note: xx=SMP board (01=Bottom SMP
board; 10=Top SMP board; 11=Bottom
SMP board and Top SMP board)
204-210-0xx (Test Failed)
Note: xx=SMP board (01=Bottom SMP
board; 10=Top SMP board; 11=Bottom
SMP board and Top SMP board)
206-xxx-000 (Failed Diskette Drive test)
215-xxx-000 (Failed CD-ROM test)
217-xxx-000 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-001 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-002 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-003 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
217-xxx-004 (Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed disk
number refers to the RAID logical array.
222
xSeries 445 Type 8870: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Isolate failing DIMM:
a. Replace a DIMM in bank with a "known good" DIMM.
b. Rerun memory diagnostic for the failing bank on failing SMP
Board.
c. If test fails, mark replaced DIMM as "good" DIMM.
d. If test passes, mark replaced DIMM as "bad" DIMM.
e. If DIMM tested is "bad", remove it and replace it.
f. If DIMM tested is "good", do not replace it.
2. Repeat steps 1a through 1f with other DIMMs in failing bank until
error is fixed.
3. If error is not fixed, replace SMP Board Y.
1. Microprocessor n
2. SMP board
1. Reload BIOS code.
2. SMP1 board (bottom).
1. Run Quick Memory Diagnostic All Banks.
2. System BIOS code problem; see PCDR log.
1. Run Quick Memory Diagnostic All Banks.
2. If test runs without failure, update system BIOS code.
3. SMP Board xx.
1. Rerun test with a different diskette.
2. Diskette drive
3. Media Bay card
1. Rerun test with a different CD.
2. CD-ROM drive
3. Media Bay card
Hard disk drive 1
Hard disk drive 2
Hard disk drive 3
Hard disk drive 4
Hard disk drive 5

Advertisement

Table of Contents
loading

Table of Contents