Operational Check Of Fans (Function Code 78) - Brother MFC-9320CW Service Manual

Color fax/mfc
Hide thumbs Also See for MFC-9320CW:
Table of Contents

Advertisement

1.4.25 Operational check of fans (Function code 78)

<Function>
This function is to check whether each of fans is operating correctly or not. The operation of
the following fans is checked respectively, and their operating states (rotation speed 100 %,
rotation speed 50 %, or OFF) are displayed.
LCD
FU
PS
<Operating procedure>
(1) Press the 7 and 8 buttons in this order in the initial state of the maintenance mode.
The indication will appear on the LCD as shown in the figure below.
(2) Press the Start/Black button to check the next item. For operation check, spin or stop
fans actually on each item.
(3) Press the Stop/Exit button so that the machine stops checking the fans, beeps for one
second and returns to the initial state of the maintenance mode.
■ Location of fans
Parts name
Main fan
Evacuate hot air of the fuser unit.
LV fan
Evacuate hot air of the Low-voltage power supply PCB.
Fig. 7-21
Main fan
Fig. 7-22
7-47
Description
Exhaust
LV fan
Confidential