Raw Tcp/Ip Printing; Configuring Raw Tcp/Ip Settings; Configuring Raw Tcp/Ip Advanced Settings - Xerox WorkCentre 7800 Series System Administrator Manual

Multifunction printer
Hide thumbs Also See for WorkCentre 7800 Series:
Table of Contents

Advertisement

Network Connectivity

Raw TCP/IP Printing

Raw TCP/IP is used to open a TCP socket-level connection over Port 9100, and stream a print-ready file
to the printer input buffer. It then closes the connection either after sensing an End Of Job character in
the PDL or after expiration of a preset timeout value. Port 9100 does not require an LPR request from the
computer or the use of an LPD running on the printer. Raw TCP/IP printing is selected in Windows as the
Standard TCP/IP port.

Configuring Raw TCP/IP Settings

In CentreWare Internet Services, click Properties > Connectivity > Setup.
1.
2.
Under Protocol, next to Raw TCP/IP Printing, click Edit.
3.
Under Protocol, select Enabled.
Next to TCP Port Number, ensure that Port 1 is set to 9100.
4.
To emulate HP JetDirect EX Plus 3, set Port 2 to 9101 and Port 3 to 9102.
5.
Next to Bidirectional, for each active port, select Enabled.
6.
Next to Maximum Connections per Port, for each active port, type a number from 1 through 32.
7.
Next to End of Job Timeout, for each active port, type a time in seconds from 0 through 1800.
Next to PDL Switching, for each active port, select Enabled as needed. PDL Switching allows the
8.
printer to switch automatically between multiple supported PDLs within a single job.
Click Apply to save the new settings or Undo to retain the previous settings.
9.

Configuring Raw TCP/IP Advanced Settings

On the Raw TCP/IP Printing page, click the Advanced tab.
1.
2.
Under Connections, set the following:
Set the Maximum Connections per port between 1–32. The default port value is 32.
To allow concurrent jobs to process for each port connection, type a number between 0–500
jobs in each port. Type 0 to allow unlimited concurrent jobs.
To limit the number of jobs that are active for each port connection, type a number between
0–32768. Type 0 to allow unlimited number of active jobs.
3.
Under Job Boundary Determination:
Type the End of Job Timeout between 0–1800 seconds to specify the amount of time to pass
before a job processes with an End of Job character. The default time is 300 seconds. Type 0
to disable end of job detection by timeout.
4.
Under Backchannel Data:
Enable Backchannel Data Transmission to Client, then, enable Out of Order Backchannel
Data to allow data from several jobs to be interspersed.
Note:
Out of Order Backchannel Data is only available when Backchannel Data Transmission to
Client is enabled.
46
WorkCentre 7800 Series Multifunction Printer
System Administrator Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 7220Workcentre 7225

Table of Contents