T R U M A S 3004 SPACE HEAT ER
S 3004 Space heater
Note: Surfaces become hot in use. Guards
provided do not give full protection for the
young or elderly.
Note: The S3004 is primarily a gas heater
with supplementary 230v heating.
Safety Instructions
In case of gas system leaks or gas smell:
• Put out all naked flames
• Do not smoke
• Switch off equipment
• Close gas cylinders
• Open doors and windows
• Do not use any electrical switches
• Allow the whole system to be checked by
an expert!
An opened skylight / lifting roof around the
exhaust cowl involves the danger of exhaust
gas entering the vehicle interior. The heating
may only be operated with the skylight / lifting
roof closed where necessary.
Note: Only experts may carry out
repair work!
A new O-ring must be mounted each time the
exhaust is dismantled.
Guarantee claims, warranty claims and
acceptance of liability will be ruled out in the
event of the following:
• Modifications to the unit (including
accessories)
• Modifications to the exhaust duct and
the cowl
• Failure to use original Truma parts as
replacement parts and accessories
• Failure to follow the installation and operating
instructions
It also becomes illegal to use the appliance,
and in countries this even makes it illegal to
use the vehicle.
98
Note: The vehicle owner is responsible for
arranging inspection
Liquid gas devices may not be used while
refuelling, in multi-storey car parks, garages or
on ferries.
Slight development of smoke and odours can
occur when commissioning a new factory
device (or after a longer period out of use). It is
appropriate to immediately allow the device to
burn on the highest power and ensure good
ventilation of the room.
An unusual burner noise or raising of the flame
points to a controller defect and makes an
inspection of the controller necessary.
Heat sensitive objects (e.g. spray cans) may
not be stored in the heating installation area as
high temperatures can occur.
Only suitable controller connection hoses that
correspond with the national requirements may
be used for the country of destination. These
must be regularly checked for brittleness.
Pressure regulating devices and hoses must
be replaced with new ones no more than 10
years after their date of manufacture (every
8 years if used commercially). This is the
responsibility of the operator.
Important operating notes
The combustion air intake under the vehicle
floor must be kept clear of dirt and slush.
The exhaust cowl must always be placed free
in the air flow during operation of the heating.
Roof structures can disturb the function of the
heating.
The cowl must be cleared of snow before
commissioning the heating system in winter.
For winter or permanent camping, we
recommend the attachable cowl extension set
SKV (3 x 15cm - part no. 30690-00) on the
cowl.
Should the heating system keep going out
in extreme wind conditions or upon use in
winter, we recommend use of a cowl extension
AKV (15cm = part no. 30010-20800) or an
additional suitable cowl top.