11. Fault messages
Gas failure
If an error occurs in the system, the display will
show the reason. This is only displayed when
the panel is on standby.
Battery too low: If the vehicle, boat or build-
ing has a battery voltage of less than 10.5V,
the boiler stops. It is automatically reset when
the voltage reaches 11V.
Fan failure: Faulty fan speed. In order to
reset, disconnect 12V from the boiler and
reconnect (automatic reset after 5 minutes).
Gas failure: Gas finished. Reset by switching
off and restarting the boiler in accordance with
item 1.
Overheat red fail: Overheating protection (red
cable) triggered. To reset, disconnect 12V from
the boiler and reconnect.
Overheat blue fail: Overheating protection
(blue cable) triggered. To reset, disconnect 12V
from the boiler and reconnect.
126
+22°C
Window open: Window open, the boiler
stops for gas. Gas operation in the boiler
starts again when the window is closed. The
electrical operation remains in function. Check
the vehicle, boat or building manual to see
whether this function is installed.
Connection failure: There is a connection
fault between boiler and panel. To reset, dis-
connect 12V from the boiler and reconnect.
Connection fail ext: Communication error
between Alde's panel and external panel.
Panel failure 1: Panel fault.
Panel failure 2: Panel fault.
12. Emergency start
• Disconnect the 12V cable and the cable to
the panel on the boiler.
• Connect a cable between 2 and 9 in the
connector on the boiler.
• Reconnect 12V to the boiler
Now the boiler starts with gas and 1kW.