Swift Motorhome Owners Service Manual page 96

Hide thumbs Also See for Motorhome:
Table of Contents

Advertisement

Note: If just the cold water system is
being used, without water heater, the heater
tank is also filled up with water. Therefore,
order to avoid damage through frost, the
water contents must be drained by opening
the drain valve when the system is no longer
in use.
Draining the water heater
1. Disconnect power for water pump (main
switch or pump switch).
2. Open hot water taps in bathroom
and kitchen.
3. Open safety/drain valve: Lever in vertical
position, (Fig. 1) position (f).
4. The water heater is now drained directly
to the outside via the safety/drain valve.
Check that the water contents have been
completely drained (10 litres).
Gas operating instructions
!
WARNING: Never operate the water
heater without water in it!
1. Remove cowl cover.
Fig. 2
2. Open gas cylinder and open the gas shut off
valve at the manifold.
3. Turn on the heater by moving the central
rocker switch to the 50ºC or 70ºC position
as desired. (Fig 3).
Fig. 3
Ultrastore
a
a = Red LED "Failure"
b = Water heater "On" 50 °C or 70 °C
c = Water heater "Off"
4. After 5 seconds clicking sound will be heard
from water heater, as boiler attempts to
light. Outer collar ( a ) in control module
will turn Red if boiler fails to light - If boiler
does fail to light, turn switch back to central
position ( c ), wait 5 minutes, and then
repeat step 3.
5. If there is air in the gas supply line, it may
take up to a minute before the gas is
available for combustion. If the appliance
switches to "Failure" during this period,
switch off the appliance - wait 5 minutes -
and switch on again!
Switching off (gas operation)
Switch off the water heater by moving the
rocker switch to the central position. (Fig 3).
!
WARNING: Drain the water heater if
there is a risk of frost!
If the water heater is not to be used for a
longer period, mount cowl cover and close the
heater gas shut off valve at the manifold.
Note: There shall be no claim under
guarantee if this point is not observed.
Always remove the cowl cover prior to
operating the water heater!
!
WARNING: Care should be taken to
ensure adequate ventilation of the flue at all
times. It is inadvisable to inhale exhaust fumes.
b
50°
c
b
70°
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents