Technical data
Determined in accordance with EN 624 or
Truma test conditions
Device category
I
in accordance with EN 437
3 B/P
Type of gas
Liquid gas (propane/butane)
Operating pressure
30mbar (see type plate)
Water contents
10 litres
Heating up time from approx 15
Boiler approx 20 minutes (measure according
to EN15033)
Heater + boiler approx 80 min
Water pressure
max 2.8 bar
Rated thermal output
(automatic output levels)
Gas operation
Combi 4 E: 2000 W / 4000 W
Combi 6 E: 2000 W / 4000 W / 6000W
Electrical operation
Combi 4 E / Combi 6 E: 900 W / 1800 W
Mixed operation (gas and electrical)
Combi 4 E: max. 3800 W
Combi 6 E: max. 5800 W
Gas consumption
Combi 4 E: 160-320 g/h
Combi 6 E: 160-480 g/h
Readiness-heat power requirement Combi 4 E
/ Combi 6 E:
Gas operation 5.2 g/h
Air delivery volume
(free-blowing without hot-air pipe)
Combi 4 E:
with 3 hot-air outlets max. 249 m3/h
with 4 hot-air outlets max. 287 m3/h
Combi 6 E:
with 4 hot-air outlets max. 287 m3/h
Current input at 12 V
heater +boiler
Combi 4 E: Short-term max. 5.6 A (average
power consumption 1.1 A)
Combi 6 E: Short-term max. 5.6 A (average
power consumption 1.3 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Heating element FrostControl (optional): maxi-
mum 0.4 A
C to 60
C
O