Operation with batteries
(internal power supply)
Indicator
Fault
(3) and (8)
Flame not ignited
flashing brightly
(3) and (7)
Burner defective
or cooling unit
flashing brightly
defective
Acoustic signal at
Undervoltage
15 second intervals
detection (internal
batteries)
Automatic switch-
Refrigerator does
ing from external
not function, gas
to internal power
operation not
supply does not
possible although
function (absence
the batteries are
of the onboard 12V
inserted
power supply for
the electronics)
Remedy
Check gas supply (gas bottle, gas valve)
Press the (8) button after clearing the fault
Check burner, burner nozzles, if necessary con-
tact Customer Service and arrange replacement
Replace batteries
Switch off the refrigerator and start again
The onboard power supply was interrupted during
the starting of the gas operation
Note: No automatic switching is performed during
the ignition.