Advanced Entry Calibration (continued)
Step
Action
Use the buttons to set the Gain
Number determined in the
L
previous step. Press ENTER to
enable the setting.
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Printhead Assembly.
Place the label over the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as P.
(B) Raise the Printhead Assembly.
M
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Printhead Assembly.
Record the sensor reading as G (or
M).
(C) Raise the Printhead Assembly.
Remove all media from the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as E.
Gain Number
18
Chapter 3 - Printer Operation
Displayed Message
TRAN SENSOR GAIN
yyy
(0 - 31)
18
TRAN SENSOR GAIN
yyy
(0 - 31)
18
Selected Gain Table
Paper
Gap (or Mark)
173
42
Comment
This example uses Gain Number
18.
Where "yyy" is a numerical value
representing the current sensor
reading.
The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Empty
9
29