Requirements on cable actuation

See
General note
The two throttles have to be controlled by two separate Bowden cables
Bowden cable
working synchronously.
Adjust the cables to a free travel of 1 mm (.04 in.).
Effectivity: 912 Series
Edition 2/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
2
Part
1
Choke shaft
2
Marking
3
Cable engagement
Fig. 10.
Non-compliance can result in serious injuries or death!
WARNING
WARNUNG
With throttle lever not connected the throttle valve will
remain fully open.
The starting position of the throttle valve is there-
fore full throttle!
Therefore never start the engine without connecting
the throttle lever first.
Non-compliance can result in serious injuries or death!
WARNUNG
WARNING
The cable actuations being used must not be affected
at all by vibrations emanating from the engine or the
airframe.
1