2) Exhaust system requirements

General note
2.1)

Technical data

See
- Average radius of exhaust manifold: at least 40 mm (1.57 in.)
- Inner diameter of manifold pipe: at least 28 mm (1.10 in.)
- Volume of damping element: approx. 5 l (1.32 USgal)
- Back pressure at maximum power: max. 0.2 bar (2.9 psi) measured in
2.2)
If a GENUINE-ROTAX exhaust is not used
The four prefitted exhaust sockets with exhaust flange and lock nuts must
General note
be used.
Exhaust sockets material: X6CrNiTi 1810 (DIN 1.4541)
Tightening torque of M8 lock nuts: 15 Nm (133 in.lb).
NOTE:
Graphic
Fig. 3
Effectivity: 912 Series
Edition 2/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
Install heat shields in required areas (fuel, oil, coolant
NOTICE
WARNUNG
hoses or tubes) and/or on the electronic components.
Because of the high temperatures, provide suitable
protection against accidental contact.
Secure exhaust system by suitable means according
NOTICE
WARNUNG
to installation requirements (Lockwire, heat-resistant
silicone to dampen the exhaust spring etc.).
Fig. 3.
each case approx. 100 mm (3.94 in.) beyond the end of the exhaust
flange)
The exhaust flange does not touch the cylinder head.
08810
78-00-00
page 5
August 01/2012