Figure - Cisco 6260 Installation Manual

Hide thumbs Also See for 6260:
Table of Contents

Advertisement

Installation Procedures

Figure 4-5

Remove the covering from exactly the specified length of each power wire. If you strip too much of
Warning
the covering, exposed wire protruding from the terminal block will create an electrical hazard. If you
strip too little of the covering, the wire may not make a good contact with the terminal, or it may not
be held securely in place in the terminal block.
Use a flat-head screwdriver to turn all three screws on the terminal block counterclockwise to open the
Step 4
terminal connectors: + (positive), – (negative), and ground. This step ensures that the correct opening is
presented for the wires, as shown in
Figure 4-6
Cisco 6260 Hardware Installation Guide
4-10
Strip and Square Off Power and Ground Wires
Positioning the Power and Ground Terminals to Accept Wires
O K
U T
I N P
A I L
T F
Y 1
O U
R A
N T
Y 2
F A
R A
N T
F A
Correct
terminal
position
(open)
O K
U T
I N P
A I L
T F
Y 1
O U
R A
N T
Y 2
F A
R A
N T
F A
Incorrect
terminal
position
(closed)