Alarms
The source of the OC-3c alarms in
ATM0/2 (the subtending interface).

Table 5-13 OC-3c/Synchronous Transfer Mode (STM-1) Network Interface Alarms

Alarm
Loss of Cell Delineation
Path RDI Received
Path AIS Received
Loss of Pointer
Line RDI
Line AIS Received
Loss of Frame
Loss of Signal
Signal Label Mismatch
The source of the E3 alarms in
ATM0/2 (subtending interface), or ATM0/2 (subtending interface).

Table 5-14 DS3/E3 Network Interface Alarms

Alarm
Loss of Cell Delineation
RAI Received
Yellow Alarm Received
AIS Received
OOF Received
LOS Detected
PLCP LOF Detected
Cisco 6260 Hardware Installation Guide
5-18
Table 5-13
is one of the following interfaces: ATM0/1 (the trunk) or
Severity
Description
Critical
Loss of cell delineation on a SONET line.
Critical
Path Remote Defect Indication was received on a SONET
line. This is equivalent to Path Far End Receive
Failure (FERF).
Critical
Path Alarm Indication Signal was received on a
SONET line.
Critical
Loss of pointer condition on a SONET line.
Critical
Line Remote Defect Indication received on a SONET line.
This is equivalent to line Far End Receive Failure (FERF).
Critical
Line Alarm Indication Signal received on a SONET line.
Critical
LOF condition on a SONET line.
Critical
LOS detected on the SONET line.
Minor
Incorrect payload type signal label mismatch on a
SONET line.
Table 5-14
is one of the following interfaces: ATM0/1 (the trunk),
Severity
Description
Critical
The DS3/E3 line is experiencing a loss of cell delineation.
Critical
The DS3/E3 line is receiving a remote alarm indication.
Critical
The DS3/E3 line is receiving a yellow alarm, indicating
that another device has detected a failure that might be in
this device.
Critical
The DS3/E3 line is receiving an Alarm Indication Signal.
Critical
The DS3/E3 line has detected an Out of Frame condition.
Critical
The DS3/E3 line has detected Loss of Signal at the framer.
Critical
The DS3/E3 line has detected a Physical Layer
Convergence Procedure Loss of Frame error.