A
CM20
Assign the access code for Wake Up call set or
reset.
NOTE:
This data assignment is not required
when Wake Up is set by PMS.
When providing the DAT as the internal an-
nouncement source, assign the access code to
record, replay, and delete a message, respec-
tively.
CM48
Designate the type of tone source for Wake Up
call.
NOTE:
When the second data is set to "Ex-
ternal Tone Source", system reset is
required.
CM10
When an External Announcement Machine is
required, assign the COT card and DK card to
required LEN.
NOTE 1:
The DK card number must be as-
signed to the first LEN (level 0) and
the third LEN (Level 2).
B
DESCRIPTION
HOTEL SYSTEM PROGRAMMING
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A024: Wake Up set from guest
A025: Wake Up cancel from guest
A027: Wake Up set from administrative
station with Single Wake Up Time
operation
A028: Wake Up set from administrative
station with Multiple Wake Up Time
operation
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A100: Record
A101: Replay
A102: Delete
Y=1
(1)
00: Tone Source of Wake Up Call
(2)
XX 00
XX: 00: No Tone
02: External Tone Source
05: Digital Announcement Trunk
14: Hold Tone Source on MP card
15: Internal Tone Generator
(1)
000-763: LEN
(2)
DB00-DB09: Interface card No. for Exter-
E800-E831 : DK Card
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE 2:
– 773 –
AUTOMATIC WAKE UP
DATA
NOTE
NOTE
INITIAL
nal Announcement Machine
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface of MP card by setting
CM44.
NWA-008845-001 Rev.5.0