Philips Sopho 2000 IPS User Manual page 539

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

To provide External Hold Tone Source through the COT and DK card:
START
CM10
Assign the COT and DK for interface with Ex-
ternal Hold Tone Source to required LEN.
NOTE 1:
NOTE 2:
CM14
Assign the COT and DK for interface with Ex-
ternal Hold Tone Source to required LEN.
[Series 3200 R6.2 software required]
NOTE 1:
NOTE 2:
CM08
Specify ON/OFF condition for external relay/
external key on MP built-in DK00 card.
A
DESCRIPTION
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
The COT card number must be as-
signed for each tenant. One Exter-
nal Hold Tone Source can be
provided per tenant.
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
The COT card number must be as-
signed for each tenant. One Exter-
nal Hold Tone Source can be
provided per tenant.
(1)
000-763: LEN
(2)
DA00-DA09: COT Card No.
E800-E831 : DK Card No.
For PIM0/1 : E800-E807
For PIM2/3 : E808-E815
For PIM4/5 : E816-E823
For PIM6/7 : E824-E831
NOTE 3:
(1)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
(2)
DA00-DA09: COT Card No.
E800-E831 : DK Card No.
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
NOTE 3:
(1)
700
(2)
0 : ON (Ground Start)
OFF (Ground Off [Open])
1 : ON (Ground Off [Open])
OFF (Ground Start)
– 521 –
MUSIC ON HOLD
DATA
NOTE 2
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface on MP card by setting
CM44.
NOTE 2
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface on MP card by setting
CM44.
NWA-008845-001 Rev.5.0
JULY/01/2006