MCI Programming
After AP Initialization, do the following programming.
Call Forwarding to the VMS stations, and UCD Group/Station Hunting Group set to the VMS stations are
required. For these feature programming, refer to each feature in this manual.
START
CM08
Specify the type of VMS which is accommo-
dated to the system.
NOTE:
CM12
Specify the type of the VMS Station.
NOTE:
CM08
Specify MSG display on the D
Specify Message Waiting control from VMS
with MCI to all stations.
NOTE:
Specify whether Message Waiting from the
VMS is provided for the called station when a
forwarded call is terminated to the VMS via
CCIS.
A
DESCRIPTION
For VMS with MCI, set the 2nd data
"0".
CM12 Y=25 is effective only when
CM08>443 is set to "0".
term
.
MW lamp control is only available
to the stations in the opposite PBX
connected with CCIS via MCI.
Station dialing MW access codes
are not allowed over CCIS.
MESSAGE CENTER INTERFACE (MCI)
(1)
443
(2)
0 : Depends on CM12 Y=25
1 : VMS with DTMF
Y=25
(1)
X-XXXXXXXX: Station No.
(2)
0 : VMS with DTMF
3 : VMS with MCI
(1)
025
(2)
0 : MSG (only)
1 : MSG X (X: Number of message)
(1)
444
(2)
0 : Available
1 : Not available
(1)
376
(2)
0 : To provide
1 : Not provided