A
CM12
Assign Service Restriction Class A for Paging
Access to the required stations.
CM15
Allow Paging Access in Service Restriction
Class A assigned by CM12 Y=02.
CM08
Specify the method of the starting AMP relay
circuit.
NOTE 1:
Set the second data to 0 when one
Paging trunk is connected with mul-
tiple AMP relay circuits or with two
AMP relay circuits simultaneously.
NOTE 2:
Set the second data to 1 when one
Paging trunk is connected with one
AMP relay circuit.
Specify the method of starting AMP relay cir-
cuit connection.
NOTE 1:
This command is effective only when
the second data of CM08>734 is set
to 0.
NOTE 2:
Set the second data to 0 when one
Paging trunk is connected with two
AMP relay circuits simultaneously.
NOTE 3:
Set the second data to 1 when one
Paging trunk is connected with mul-
tiple AMP relay circuits or with one
AMP relay circuit.
B
DESCRIPTION
EXTERNAL PAGING WITH MEET-ME
Y=02
(1)
X-XXXXXXXX: My Line No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class A
Y=08
(1)
00-15: Service Restriction Class A as-
(2)
1 : Allow
(1)
734
(2)
0 : To specify by Access Code
1 : To specify per trunk
(1)
735
(2)
0 : To connect with two AMP relay cir-
cuits
1 : To connect with one AMP relay circuit